Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Guided tissue regeneration around dental implants in immediate extraction sockets: comparison of e-PTFE and a new titanium membrane
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 14 , Issue 3
May/June 1994

Pages 243-254


Guided tissue regeneration around dental implants in immediate extraction sockets: comparison of e-PTFE and a new titanium membrane

Celletti/Davarpanah/Etienne/Pecora/Tecucianu/Djukanovic/Dona


PMID: 7995694
DOI: 10.11607/prd.00.0086

To evaluate the efficacy of guided tissue regeneration around exposed implant threads, 16 implants were placed into fresh extraction sockets in beagle dogs. Polytetrafluoroethylene (e-PTFE) membranes and titanium membranes were used to cover the defects around implants. A control group did not receive any membranes. Results were evaluated histologically. The average gain in bone height was 2.1 mm for e-PTFE sites, 0.8 mm for titanium membranes, and 2.9 mm for control sites. The greatest gain in bone levels was seen for two sites that received e-PTFE membranes and remained covered for the entire evaluation interval. Within the limits of this study, clinical and histologic evidence demonstrated that, when primary coverage is maintained, the use of e-PTFE membranes can significantly enhance bone regeneration around implants.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help